Solis 6KW Single Phase Hybrid LV Inverter Pro
SolisLog in for pricing
Solis S6 Advanced Power Hybrid Inverter
Features:
- Generator connectivity with multiple input methods and automatic generator On/Off control
- Automatic UPS switching
- 10 second 200% surge power backup overload capability
- Supports 1ph and 3ph flexible connection with max 36kW in parallel
- Up to 135A max charge/discharge current
- 6 customisable charge/discharge time settings
- Compatible with lead-acid and lithium batteries, with multiple battery protection features
- Supports peak shaving control in both "self-use" and "generator" mode
Datasheet:
Models |
3K |
3.6K |
5K |
6K |
Input DC (PV side) |
||||
Recommended max. PV power |
4.8 kW |
5.76 kW |
8 kW |
9.6 kW |
Max. input voltage |
600 V |
|||
Rated voltage |
330 V |
|||
Start-up voltage |
90 V |
|||
MPPT voltage range |
90-520 V |
|||
Max. input current |
16 A / 16 A |
|||
Max. short circuit current |
24 A / 24 A |
|||
MPPT number/Max. input strings number |
2/2 |
|||
Battery |
||||
Battery type |
Li-ion / Lead-acid |
|||
Battery voltage range |
40-60 V |
|||
Max. charge / discharge power |
3 kW |
3.6 kW |
5 kW |
6 kW |
Max. charge / discharge current |
70 A |
80 A |
112 A |
135 A |
Communication |
CAN/RS485 |
|||
Output AC (Grid side) |
||||
Rated output power |
3 kW |
3.6 kW |
5 kW |
6 kW |
Max. apparent output power |
3.3 kVA |
4 kVA |
5.5 kVA |
6.6 kVA |
Operation phase |
1/N/PE |
|||
Rated grid voltage |
220 V / 230 V |
|||
Rated grid frequency |
50 Hz / 60 Hz |
|||
Rated grid output current |
13.6 A / 13.0 A |
16.4 A / 15.7 A |
22.7 A / 21.7 A |
27.3 A / 26.1 A |
Max. output current |
15 A |
20 A |
25 A |
30 A |
Power factor |
>0.99 (0.8 leading - 0.8 lagging) |
|||
THDi |
<2% |
|||
Input AC (Grid side) |
||||
Input voltage range |
187 - 253 V |
|||
Max. input current |
20 A |
25 A |
32 A |
40 A |
Frequency Range |
45-55 Hz / 55-65 Hz |
|||
Output AC (Back-up) |
||||
Rated output power |
3 kW |
3.6 kW |
5 kW |
6 kW |
Max. apparent output power |
2 times of rated power, 10 s |
|||
Back-up switch time |
<4 ms |
|||
Rated output voltage |
1/N/PE, 220 V / 230 V |
|||
Rated frequency |
50 Hz / 60 Hz |
|||
Rated output current |
13.6 A / 13.0 A |
16.4 A / 15.7 A |
22.7 A / 21.7 A |
27.3 A / 26.1 A |
Max. output current |
20 A |
25 A |
32 A |
40 A |
Max. AC Passthrough current |
35 A |
35 A |
40 A |
40 A |
THDv (@linear load) |
<2% |
|||
Efficiency |
||||
Max. efficiency |
> 97.5% |
|||
EU efficiency |
> 96.2% |
|||
Protection |
||||
DC reverse-polarity protection |
Yes |
|||
Ground Fault Monitoring |
Yes |
|||
Integrated AFCI (DC arc-fault circuit protection) |
Yes (1) |
|||
Protection class/Over voltage category |
I/II |
|||
General Data |
||||
Dimensions (W*H*D) |
406*560*205 mm |
|||
Weight |
24 kg |
|||
Topology |
High frequency isolation (for battery) |
|||
Operating ambient temperature range |
-40 ~ +60°C |
|||
Ingress protection |
IP66 |
- single or three-phase:
- single-phase
- Frequency:
- 50
- Voltage:
- 220
- Battery Voltage:
- 48