Solis 4.6KW Single Phase String Inverter

Solis
SKU:
S6-GR1P4.6K
Availability:
4-6 weeks

Log in for pricing

Weight:
14.00 KGS
Width:
38.20 (cm)
Height:
64.90 (cm)
Depth:
24.00 (cm)
Current Stock:
Minimum Purchase:
10 units

Download Datasheet

DOWNLOAD DATASHEET

Solis 4.6KWSinglephaseDualMPPT,withDCSwitch

Features:

  • Max. efficiency 97.7%
  • String current up to 14A
  • Super high frequency switching technology
  • Wide voltage range and low startup voltage
  • 2 MPPT design with precise MPPT algorithm
  • Intergrated Export Power Manager (EPM)
  • AFCI protection, proactively reduces fire risk
  • Compact and lightweight
  • Friendly and adaptable connection to the grid

Datasheet:

Model

2.5K

3K

3.6K

4K

4.6K

5K

6K

Input DC

Recommended max. PV power

3.75 kW 4.5 kW 5.4 kW 6 kW 6.9 kW 7.5 kW 9 kW

Max. input voltage

550 V

600 V

Rated voltage

250 V

330 V

Start-up voltage

60 V

120 V

MPPT voltage range

50-450 V

90-520 V

Max. input current

14 A / 14 A

Max. short circuit current

22 A / 22 A

MPPT number/Max. input strings number

2/2

Output AC

 

Rated output power

2.5 kW

3 kW

3.6 kW

4 kW

4.6 kW

5 kW

6 kW

Max. apparent output power

2.8 kVA

3.3 kVA

4 kVA

4.4 kVA

5 kVA

5 kVA

6 kVA

Max. output power

2.8 kW

3.3 kW

4 kW

4.4 kW

5 kW

5 kW

6 kW

Rated grid voltage

 

 

 

1/N/PE, 220 V / 230 V

 

 

 

Rated grid frequency

 

 

 

50 Hz / 60 Hz

 

 

 

Rated grid output current

11.4 A / 10.9 A

13.6 A / 13.0 A

16.0 A / 15.7 A

18.2 A / 17.4 A

20.9 A / 20.0 A

22.7 A / 21.7 A

27.3 A

Max. output current

13.3 A

15.7 A

16.0 A

21.0 A

23.8 A

25.0 A

27.3 A

Power factor

>0.99 (0.8 leading - 0.8 lagging)

THDi

<3%

Efficiency

 

Max. efficiency

97.3%

97.3%

97.6%

97.7%

EU efficiency

96.5%

96.6%

97.1%

97.1%

Protection

 

 

 

 

DC reverse-polarity protection

Yes

Short circuit protection

Yes

Output over current protection

Yes

Surge protection

Yes

Grid monitoring

Yes

Anti-islanding protection

Yes

Temperature protection

Yes

Integrated AFCI (DC arc-fault circuit protection)

Yes (1)

Integrated DC switch

Optional

General Data

 

Dimensions (W*H*D)

310*543*160 mm

Weight

11 kg

11.2 kg

12 kg

Topology

Transformerless

Self-consumption  (night)

<1 W

Operating ambient temperature range

-25 ~ +60°C

Relative humidity

0-100%

Ingress protection

IP66

Cooling concept

Natural convection

Max. operation altitude

4000 m

Grid connection standard

G98(2) or G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 / UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA

Safety/EMC standard

IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-3

Features

 

 

 

 

 

 

 

DC connection

MC4 connector

AC connection

Quick connection plug

Display

LCD

Communication

RS485, Optional: Wi-Fi, GPRS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input DC

5 Years
single or three-phase:
single-phase
Frequency:
50
Voltage:
220