Huawei 100KW Smart PV Controller

Huawei
SKU:
SUN2000-100KTL-M2

Contact us for pricing

Log in for pricing

Weight:
98.00 KGS
Width:
109.00 (cm)
Height:
75.00 (cm)
Depth:
42.00 (cm)
Current Stock:

Download Datasheet

DOWNLOAD DATASHEET

Smart PV Controller

Features:

  • 10 MPP Trackers
  • 98.8% (@480V) Max. Efficiency
  • String-level Management
  • Smart I-V Curve Diagnosis Supported
  • MBUS Supported
  • Support AFCI & Smart String Level Disconnector
  • Surge Arresters for DC & AC
  • IP66 Protection

Technical Specification

SUN2000-100KTL-M2

Efficiency

Max.efficiency

98.6%@400V,98.8%@480V

European efficiency

98.4%@400V,98.6%@480V

Input

Max.Input Voltage1

1,100 V

Max.Current per MPPT

30A

Max.Current per Input3

20A

Max.Short Circuit Currentper MPPT

40A

Start Voltage

200V

MPPT Operating Voltage Range2

200V~1,000V

Nominal Input Voltage

600 V@400Vac,720 V@480Vac

Number of MPP trackers

10

Max.input number per MPP tracker

2

Output

Nominal AC Active Power

100,000W

Max.AC Apparent Power

110,000VA

Max.AC Active Power (cosφ=1)

110,000W

Nominal Output Voltage

380V/400V/480V,3W+(N)+PE

Rated AC Grid Frequency

50Hz/60Hz

Nominal Output Current

144.4A@400V,120.3A@480V

Max.Output Current

160.4A@400V,133.7A@480V

Adjustable Power Factor Range

0.8 leading...0.8lagging

Max.Total Harmonic Distortion

<3%

Protection

Input-side Disconnection Device

Yes

Anti-islanding Protection

Yes

AC Overcurrent Protection

Yes

DC Reverse-polarity Protection

Yes

PV-array String Fault Monitoring

Yes

DC Surge Arrester

TypeII

AC Surge Arrester

TypeII

DC Insulation Resistance Detection

Yes

Residual Current Monitoring Unit

Yes

Arc Fault Protection

Yes

Smart String Level Disconnector

Yes

Communication

Display

LED indicators ; WLAN adaptor + FusionSolar APP

RS485

Yes

USB

Yes

SmartDongle-4G

Smart Dongle–4G / WLAN (Optional)

MonitoringBUS(MBUS)

Yes (isolation transformer required)

GeneralData

Dimensions(W xHxD)

1,035x700 x365mm

Weight(with mounting plate)

93kg

Operating Temperature Range

-25°C~60°C

Cooling Method

Smart Air Cooling

Max.OperatingA ltitude

4,000m (13,123ft.)

Relative Humidity

0~100%

DC Connector

Amphenol Helios H4

AC Connector

Waterproof Connector + OT / DTTerminal

Protection Degree

IP66

Topology

Transformerless

Nighttime Power Consumption

<3.5W

Standard Compliance (more availableupon request)

Certificate

EN62109-1/-2,IEC62109-1/-2,EN50530,IEC62116,IEC61727, IEC60068,IEC61683

Grid Connection Standards

VDE-AR-N4105,EN50549-1,EN50549-2,RD661,RD1699,C10/11

 

5 years
single or three-phase:
three-phase
Frequency:
50
Voltage:
400