Huawei 115KW Smart PV Controller
HuaweiLog in for pricing
Smart PV Controller
Features:
- 10 MPP Trackers
- 8% (@480V) Max. Efficiency
- String-level Management
- Smart I-V Curve Diagnosis Supported
- MBUS Supported
- Support Smart String Level Disconnector
- Surge Arresters for DC & AC
- IP66 Protection
|
Technical Specification |
SUN2000-115KTL-M2 |
|
Efficiency |
|
|
Max.efficiency |
98.6%@400V, 98.8%@480V |
|
European efficiency |
98.4%@400V, 98.6%@480V |
|
Input |
|
|
Max.Input Voltage1 |
1,100V |
|
Max.Current per MPPT |
30A |
|
Max.Current per Input |
20 A |
|
Max. Short Circuit Current per MPPT |
40A |
|
Start Voltage |
200V |
|
MPPT Operating Voltage Range2 |
200V~1,000V |
|
Nominal Input Voltage |
600V @400Vac, 720V @480 Vac |
|
Number of MPP trackers |
10 |
|
Max. input number per MPP tracker |
2 |
|
Output |
|
|
Nominal AC ActivePower |
115,000W |
|
Max.AC Apparent Power |
125,000VA |
|
Max.AC Active Power (cosφ=1) |
125,000W |
|
Nominal Output Voltage |
400 V / 480V,3W+(N)+PE |
|
Rated AC Grid Frequency |
50Hz/60Hz |
|
Nominal Output Current |
166.0 A @400 V, 138.4A @480 V |
|
Max. Output Current |
182.3 A @400 V, 151.9A @480 V |
|
Adjustable Power Factor Range |
0.8leading... 0.8 lagging |
|
Max.Total Harmonic Distortion |
<3% |
|
Protection |
|
|
Input-side Disconnection Device |
Yes |
|
Anti-islanding Protection |
Yes |
|
AC Over current Protection |
Yes |
|
DC Reverse-polarity Protection |
Yes |
|
PV-array String Fault Monitoring |
Yes |
|
DC Surge Arrester |
TypeII |
|
AC Surge Arrester |
TypeII |
|
DCInsulation Resistance Detection |
Yes |
|
Residual Current Monitoring Unit |
Yes |
|
Smart String Level Disconnector |
Yes |
|
Communication |
|
|
Display |
LED indicators; WLAN adaptor + FusionSolarAPP |
|
RS485 |
Yes |
|
USB |
Yes |
|
Smart Dongle-4G |
Smart Dongle–4G / WLAN (Optional) |
|
Monitoring BUS (MBUS) |
Yes (isolation transformer required) |
|
General Data |
|
|
Dimensions (WxHxD) |
1,035x700 x365mm |
|
Weight (with mounting plate) |
≤ 93kg |
|
Operating Temperature Range |
-25°C~60°C |
|
Cooling Method |
Smart Air Cooling |
|
Max. Operating Altitude |
4,000m (13,123ft.) |
|
Relative Humidity |
0~100% |
|
DC Connector |
Amphenol Helios H4 |
|
AC Connector |
Waterproof Connector + OT/DT Terminal |
|
Protection Degree |
IP66 |
|
Topology |
Transformerless |
|
Nighttime Power Consumption |
<3.5W |
|
Standard Compliance (more available upon request) |
|
|
Certificate |
EN 62109-1/-2, IEC 62109-1/-2, IEC 62116, IEC 61727, IEC 60068, IEC 61683 |
|
Grid Connection Standards |
VDE-AR-N4105, EN 50549-1, EN 50549-2, RD 661, RD 1699, C10/11 |
- single or three-phase:
- three-phase
- Frequency:
- 50
- Voltage:
- 400