Huawei 30KW Smart PV Controller
HuaweiLog in for pricing
Smart PV Controller
Features:
• Smart
     - 8strings intelligent monitoring
• Efficient
     - Max. efficiency 98.7%
• Safe
     - Fuse free design
• Reliable
     - Type II surge arresters for DC & AC
| 
 Technical Specification  | 
 SUN2000-30KTL-M3  | 
 SUN2000-36KTL-M3  | 
 SUN2000-40KTL-M3  | 
| 
 Efficiency  | 
|||
| 
 Max. Efficiency  | 
 98.7%  | 
||
| 
 European Efficiency  | 
 98.4%  | 
||
| 
 Input  | 
|||
| 
 Max. Input Voltage 1  | 
 1,100 V  | 
||
| 
 Max. Current per MPPT  | 
 26 A  | 
||
| 
 Max. Short Circuit Current per MPPT  | 
 40 A  | 
||
| 
 Start Voltage  | 
 200 V  | 
||
| 
 MPPT Operating Voltage Range 2  | 
 200 V ~ 1000 V  | 
||
| 
 Rated Input Voltage  | 
 600 V  | 
||
| 
 Number of Inputs  | 
 8  | 
||
| 
 Number of MPP Trackers  | 
 4  | 
||
| 
 Output  | 
|||
| 
 Rated AC Active Power  | 
 30,000 W  | 
 36,000 W  | 
 40,000 W  | 
| 
 Max. AC Apparent Power  | 
 33,000 VA 3  | 
 40,000 VA  | 
 44,000 VA  | 
| 
 Rated Output Voltage  | 
 230Vac/400Vac/ 480 Vac,3W/N+PE  | 
||
| 
 Rated AC Grid Frequency  | 
 50 Hz / 60 Hz  | 
||
| 
 Rated Output Current  | 
 43.3 A  | 
 52.0 A  | 
 57.8 A  | 
| 
 Max. Output Current  | 
 47.9 A  | 
 58.0 A  | 
 63.8 A  | 
| 
 Adjustable Power Factor Range  | 
 0.8 LG ... 0.8 LD  | 
||
| 
 Max. Total Harmonic Distortion  | 
 < 3%  | 
||
| 
 Protection  | 
|||
| 
 Input-side Disconnection Device  | 
 Yes  | 
||
| 
 Anti-islanding Protection  | 
 Yes  | 
||
| 
 AC Overcurrent Protection  | 
 Yes  | 
||
| 
 DC Reverse-polarity Protection  | 
 Yes  | 
||
| 
 PV-array String Fault Monitoring  | 
 Yes  | 
||
| 
 DC Surge Arrester  | 
 Yes  | 
||
| 
 AC Surge Arrester  | 
 Yes  | 
||
| 
 DC Insulation Resistance Detection  | 
 Yes  | 
||
| 
 Residual Current Monitoring Unit  | 
 Yes  | 
||
| 
 Arc Fault Protection  | 
 Yes  | 
||
| 
 Ripple Receiver Control  | 
 Yes  | 
||
| 
 Integrated PID Recovery 4  | 
 Yes  | 
||
| 
 Communication  | 
|||
| 
 Display  | 
 LED Indicators, Integrated WLAN + FusionSolar APP  | 
||
| 
 RS485  | 
 Yes  | 
||
| 
 Smart Dongle  | 
 WLAN/Ethernet via Smart Dongle-WLAN-FE (Optional) 4G / 3G / 2G via Smart Dongle-4G (Optional)  | 
||
| 
 Monitoring BUS (MBUS)  | 
 Yes (Isolation Transformer required)  | 
||
| 
 General Data  | 
|||
| 
 Dimensions (W x H x D)  | 
 640 x 530 x 270 mm (25.2 x 20.9 x 10.6 inch)  | 
||
| 
 Weight (with mounting plate)  | 
 43 kg (94.8 lb)  | 
||
| 
 Operating Temperature Range  | 
 -25 ~ + 60 °C (-13 °F ~ 140 °F)  | 
||
| 
 Cooling Method  | 
 Natural Convection  | 
||
| 
 Max. Operating Altitude  | 
 4,000 m (13,123 ft.) (Derating above 2000 m)  | 
||
| 
 Relative Humidity  | 
 0% RH ~ 100% RH  | 
||
| 
 DC Connector  | 
 Staubli MC4  | 
||
| 
 AC Connector  | 
 Waterproof Connector + OT/DT Terminal  | 
||
| 
 Protection Degree  | 
 IP 66  | 
||
| 
 Topology  | 
 Transformerless  | 
||
| 
 NightimePower Consumption  | 
 ≤ 5.5W  | 
||
| 
 Optimizer Compatibility  | 
|||
| 
 DC MBUS Compatible Optimizer  | 
 SUN2000-450W-P  | 
||
| 
 Standard Compliance (more available upon request)  | 
|||
| 
 Safety  | 
 EN 62109-1/-2, IEC 62109-1/-2, EN 50530, IEC 62116, IEC 60068, IEC 61683  | 
||
| 
 Grid Connection Standards  | 
 IEC 61727, VDE-AR-N4105, VDE 0126-1-1, BDEW, G59/3, UTE C 15-712-1, CEI 0-16, CEI 0-21, RD 661, RD 1699, P.O. 12.3,RD 413, EN-50438-Turkey, EN-50438-Ireland, C10/11, MEA, Resolution No.7, NRS 097-2-1, AS/NZS 4777.2, DEWA  | 
||
- single or three-phase:
 - three-phase
 - Frequency:
 - 50
 - Voltage:
 - 400