Huawei 50KW Smart PV Controller
HuaweiLog in for pricing
Features:
• Higher Yields
- Up to 30% More Energy with Optimizer
• Active Safety
- AI2 Powered Active Arcing Protection
• Flexible Communication
- WLAN, Fast Ethernet, 4G Communication Supported
Technical Specification |
SUN2000-50KTL-M3 |
Efficiency |
|
Max.Efficiency |
98.5% |
European Efficiency |
98.0% |
Input |
|
Max.Input Voltage1 |
1,100V |
Max. Current per MPPT |
30A |
Max. Current per Input |
20 A |
Max. Short Circuit Current per MPPT |
40A |
Start Voltage |
200V |
MPPT Operating Voltage Range2 |
200 V ~ 1,000V |
Rated Input Voltage |
600V |
Number of Inputs |
8 |
Number of MPP Trackers |
4 |
Output |
|
Rated AC Active Power |
50,000W |
Max. AC Apparent Power |
55,000VA |
Max. AC Active Power (cosφ=1) |
55,000W |
Rated Output Voltage |
400 Vac/ 480 Vac, 3W+(N) + PE |
Rated AC Grid Frequency |
50 Hz / 60Hz |
Rated Output Current |
72.2 A @ 400Vac, 60.1 A @ 480Vac |
Max. Output Current |
79.8 A @ 400Vac, 66.5 A @ 480Vac |
Adjustable Power Factor Range |
0.8 LG ... 0.8LD |
Max. Total Harmonic Distortion |
<3% |
Protection |
|
Input-side Disconnection Device |
Yes |
Anti-islanding Protection |
Yes |
AC Overcurrent Protection |
Yes |
DC Reverse-polarity Protection |
Yes |
PV-array String Fault Monitoring |
Yes |
DC Surge Arrester |
TypeII |
AC Surge Arrester |
TypeII |
DC Insulation Resistance Detection |
Yes |
Residual Current Monitoring Unit |
Yes |
Arc Fault Protection |
Yes |
Ripple Receiver Control |
Yes |
Integrated PID Recovery3 |
Yes |
Communication |
|
Display |
LED Indicators, Bluetooth + APP |
RS485 |
Yes |
Smart Dongle |
WLAN / Ethernet via Smart Dongle-WLAN-FE(Optional) 4G/3G/2GviaSmartDongle-4G(Optional) |
Monitoring BUS(MBUS) |
Yes(Isolation Transformer required) |
Optimizer Compatibility |
|
DC MBUS Compatible Optimizer |
MERC-1100/1300W-P |
General Data |
|
Dimensions (W x H xD) |
640 x 530 x 270 mm (25.2 x 20.9 x 10.6 inch) |
Weight (with mounting plate) |
49 kg (108.1 lb) |
Operating Temperature Range |
-25°C ~ 60°C (-13°F ~ 140°F) |
Cooling Method |
Smart Air Cooling |
Max. Operating Altitude |
4,000 m (13,123 ft.) |
Relative Humidity |
0% RH ~ 100% RH |
DC Connector |
Amphenol HH4 |
AC Connector |
Waterproof Connector + OT/DT Terminal |
Protection Degree |
IP 66 |
Topology |
Transformerless |
Nighttime Power Consumption |
≤ 5.5W |
Standard Compliance (more available upon request) |
|
Safety |
EN62109-1/-2,IEC62109-1/-2,EN50530,IEC62116,IEC60068,IEC61683 |
Grid Connection Standards |
IEC 61727,VDE-AR-N4105,VDE0126-1-1,BDEW,G59/3,UTEC15-712-1,CEI0-16,CEI0-21,RD661,RD1699, P.O.12.3,RD413,EN-50438-Turkey,EN-50438-Ireland, C10/11,MEA,ResolutionNo.7, NRS097-2-1,DEWA |
- single or three-phase:
- three-phase
- Frequency:
- 50
- Voltage:
- 400