Solis 100KW Three Phase String Inverter (10 MPPT)
SolisLog in for pricing
Solis 100KWthreephase10MPPTs,withDCswitch
Features:
• Efficient
- 10 MPPTs, max. efficiency 99.0%
- > 150% DC/AC ratio
- High power tracking density 100MPPT/MW
- String current up to 16A, perfectly match large current bifacial modules
• Safe
- AFCI protection, proactively reduces fire risk
- Built-in PID recovery for better module performance (optional)
- Overvoltage load reduction and leakage current suppression technology, low failure rate
- Globally recognised branded componentry for longer life
• Smart
- Night SVG function
- Intelligent string monitoring, smart I-V curve scan
- Remote firmware upgrade with simple operation
• Economic
- Power line communication (PLC) (optional)
- DC side supports "Y" connector
Datasheet:
Models |
100K |
110K |
125K-HV |
Input DC
Max. input voltage |
1100 V |
|
Rated voltage |
600 V |
720 V |
Start-up voltage |
195 V |
|
MPPT voltage range |
180-1000 V |
|
Max. input current |
10*32 A |
|
Max. short circuit current |
10*40 A |
|
MPPT number/Max. input strings number |
10/20 |
Output AC
Rated output power |
100 kW |
110 kW |
125 kW |
Max. apparent output power |
110 kVA |
121 kVA |
137.5 kVA |
Max. output power |
110 kW |
121 kW |
137.5 kW |
Rated grid voltage |
3/N/PE, 220 V / 380 V, 230 V / 400 V |
3/PE, 480 V |
|
Rated grid frequency |
50 Hz / 60 Hz |
||
Rated grid output current |
152.0 A / 144.3 A |
167.1 A / 158.8 A |
150.4 A |
Max. output current |
167.1 A |
183.8 A |
165.4 A |
Power factor |
>0.99 (0.8 leading - 0.8 lagging) |
||
THDi |
<3% |
Efficiency |
|
||
Max. efficiency |
98.7% |
99.0% |
|
EU efficiency |
98.3% |
98.6% |
|
Protection |
|
|
DC reverse-polarity protection |
Yes |
Short circuit protection |
Yes |
Output over current protection |
Yes |
Surge protection |
DC Type II / AC Type II (AC Type I optional) |
Grid monitoring |
Yes |
Anti-islanding protection |
Yes |
Temperature protection |
Yes |
Strings monitoring |
Yes |
I/V Curve scanning |
Yes |
Integrated PID recovery |
Optional |
Integrated AFCI (DC arc-fault circuit protection) |
Yes (1) |
Integrated DC switch |
Yes |
Integrated AC switch |
Optional |
General Data
Dimensions (W*H*D) |
1065*567*344.5 mm |
||
Weight |
91 kg |
||
Topology |
Transformerless |
||
Self-consumption (night) |
<2 W |
||
Operating ambient temperature range |
-30 ~ +60°C |
||
Relative humidity |
0-100% |
||
Ingress protection |
IP66 |
||
Cooling concept |
Intelligent redundant fan-cooling |
||
Max. operation altitude |
4000 m |
||
Grid connection standard |
VDE-AR-N 4105, VDE V 0124, VDE V 0126-1-1, UTE C15-712-1, NRS 097-1-2, G98, G99, EN 50549-1/-2, RD 1699, TOR, UNE 206006, UNE 206007-1, CEI 0-21, IEC61727, DEWA |
||
Safety/EMC standard |
IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4 |
||
Features |
|
|
|
DC connection |
MC4 connector |
||
AC connection |
OT terminal (max. 185 mm²) |
||
Display |
LCD |
||
Communication |
RS485, Optional: Wi-Fi, GPRS, PLC |
- single or three-phase:
- three-phase
- Frequency:
- 50
- Voltage:
- 480