Technical Specifications
|
Models |
3K |
3.6K |
5K |
6K |
8K |
9K(21A) |
10K(21A) |
|
Input DC (PV side) |
|||||||
|
Recommended max. PV array size |
6kW |
7.2kW |
10kW |
12kW |
16kW |
18 kW |
20 kW |
|
Max. usable PV input power |
4.8kW |
5.76kW |
8kW |
9.6kW |
12.8kW |
14.4 kW |
16 kW |
|
Max. input voltage |
500 V |
||||||
|
Rated voltage |
330 V |
||||||
|
Start-up voltage |
90 V |
||||||
|
MPPT voltage range |
90-435 V |
||||||
|
Max. input current |
16 A / 16 A |
32 A / 32 A |
42 A / 42 A |
||||
| Max. current per DC input |
16 A |
21A |
|||||
|
Max. short circuit current |
20 A / 20 A |
40 A / 40 A |
48 A / 48 A |
||||
|
MPPT number/Max. input strings number |
2/2 |
2/4 |
|||||
|
Battery |
|||||||
|
Battery Type |
Li-ion / Lead-acid |
||||||
|
Battery Voltage Range |
40-60 V |
||||||
|
Max. Charge / Discharge Power |
3 kW |
3.6 kW |
5 kW |
6 kW |
8 kW |
9 kW |
10 kW |
|
Max. Charge / Discharge Current |
70 A |
80 A |
112 A |
135 A |
190 A |
200 A |
210 A |
|
Number of battery port / number of BMS port |
1/1 | ||||||
|
Communication |
CAN/RS485 |
||||||
|
Output AC (Grid side) |
|||||||
|
Rated output power |
3 kW |
3.6 kW |
5 kW |
6 kW |
8 kW |
9 kW |
10 kW |
|
Max. apparent output power |
3 kVA |
3.6 kVA |
5 kVA |
6 kVA |
8 kVA |
9 kVA |
10 kVA |
|
Operation phase |
1/N/PE |
||||||
|
Rated grid voltage |
220 V / 230 V |
||||||
|
Rated grid frequency |
50 Hz / 60 Hz |
||||||
|
Rated grid output current |
13.7 A / 13.1 A |
16.4 A / 15.7 A |
22.8 A / 21.8 A |
27.3 A / 26.1 A |
36.4 A / 34.8 A |
40.9 A / 39.1 A |
45.5 A / 43.5 A |
|
Power factor |
>0.99 (0.8 leading - 0.8 lagging) |
||||||
|
THDi |
<3% |
||||||
|
Input AC (Grid side) |
|||||||
|
Input voltage range |
187-253 V |
||||||
|
Max. input current |
21A |
25A |
32A |
40A |
50A |
60 A |
65 A |
|
Output AC (Back-up) |
|||||||
|
Rated Output Power |
3 kW |
3.6 kW |
5 kW |
6 kW |
8 kW |
9 kW |
10 kW |
|
Max. apparent output power |
2 times of rated power, 10 s |
||||||
|
Back-up switch time |
<10 ms |
||||||
|
Rated output voltage |
L/N/PE, 220 V / 230 V |
||||||
|
Rated Frequency |
50 Hz / 60 Hz |
||||||
|
Rated output current |
13.7 A / 13.1 A |
16.4 A / 15.7 A |
22.8 A / 21.8 A |
27.3 A / 26.1 A |
36.4 A / 34.8 A |
40.9 A / 39.1 A |
45.5 A / 43.5 A |
|
Max. AC Passthrough current |
35A |
35A |
40A |
40A |
50A |
60 A |
65 A |
|
THDv (@linear load) |
<2% |
||||||
|
Efficiency |
|||||||
|
Max. efficiency |
96.2% |
||||||
|
EU efficiency |
96.1% |
||||||
|
BAT charged by PV/AC Max. efficiency |
95.3% / 93.9% |
||||||
|
BAT discharged to AC Max. efficiency |
93.8% |
||||||
|
Protection |
|||||||
|
Surge protection |
Yes |
||||||
|
Output over current protection |
Yes |
||||||
|
Insulation resistance monitoring |
Yes |
||||||
|
Residual current detection |
Yes |
||||||
|
Integrated PV switch |
Yes |
||||||
|
DC reverse-polarity protection |
Yes |
||||||
|
Integrated AFCI 2.0 |
Optional |
||||||
|
Protection class/Over voltage category |
I / II (PV and BAT), III (MAINS and BACKUP and GEN) |
||||||
|
Anti-islanding protection |
Yes |
||||||
|
General Data |
|||||||
|
Dimensions (W*H*D) |
335*560*253mm |
||||||
|
Weight |
23 kg |
23.5 kg |
23.8 kg |
||||
|
Topology |
Non-isolated (PV), Isolated (Battery) |
||||||
|
Operating ambient temperature range |
-25 ~ +60°C |
||||||
|
Ingress protection |
IP66 |
||||||
|
Cooling Concept |
Natural convection |
Intelligent redundant fan-cooling |
|||||
|
Max. operation altitude |
3000 m |
||||||
|
Grid connection standard |
NRS 097-2-1, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, EN 50549-1, |
||||||
|
Safety/EMC standard |
IEC/EN 62109-1/-2, EN 61000-6-2/-3
|
||||||
- single or three-phase:
- single-phase
- Battery Voltage:
- 48
- Frequency:
- 50
- Voltage:
- 220