Introducing the S6-EH3P(75-125)K10-NV-YD-H Series. High voltage, three-phase energy storage for commercial applications. The inverter series, which boasts a maximum charge/discharge current of 100A+100A across two independently controlled battery ports, has 10 integrated MPPTs with a string current capacity of up to 20A – ensuring unmatched power delivery. Whether for on or off-grid applications, the S6-EH3P(75-125)K10-NV-YD-H series supports parallel operation of up to six units, with a backup port capable of supporting 2.0 times overload for short durations. This latest range compatible with an array of batteries, thanks to its wide voltage range, and offers peak shaving control in both "self-use" and "generator" modes.
8 Unique Features
- Compatible with 100-314Ah battery modules
- Supports faster charging with battery current up to 200A
- Powerful backup overload capability – 160% overload
- Supports 2 independent battery connections for flexible configuration
- 7-inch large screen uses U.S.-made ZEITLER industrialgrade components
- Supports max 21A PV input current, perfect match for high power PV modules
- Supports a wide power range of generator connections from 25kVA to 125kVA
- Usable PV power up to 200% inverter rated power, to improve the utilization of PV generation
S6-EH3P(75-125)K10-NV-YD-H |
||||||
Models |
75K |
80K |
100K |
125K |
||
Input DC (PV side) |
||||||
Recommended max. PV array size |
150 kW |
160kW |
200kW |
240kW |
||
Max. usable PV input power |
150 kW |
160kW |
200kW |
240kW |
||
Max. input voltage |
1000V |
|||||
Rated voltage |
600V |
|||||
Start-up voltage |
180V |
|||||
MPPT voltage range |
150 - 950V |
|||||
Max. input current |
10 x 42 A |
|||||
Max. short circuit current |
10x 60 A |
|||||
MPPT number / Max. input strings number |
10 / 20 |
|||||
Battery |
||||||
Battery type |
Li-ion |
|||||
Battery voltage range |
300 - 950 V |
|||||
Max.charge / discharge current |
200 A / 100 A + 100 A |
|||||
Number of battery ports |
2 |
|||||
Max. charge / discharge current of each port |
100 A |
|||||
Communication |
CAN / RS485 |
|||||
Output AC (Grid side) |
||||||
Rated output power |
75 kW |
80 kW |
100kW |
125 kW |
||
Max. apparent output power |
75 kVA |
80kVA |
100kVA |
125 kVA |
||
Rated grid voltage |
3/N/PE, 220 V / 380 V, 230 V / 400 V |
|||||
Rated grid frequency |
50 Hz / 60 Hz |
|||||
Rated grid output current |
114 A / 108.3 A |
121.6 A / 115.5 A |
152 A / 144.3 A |
180.4 A / 189.9 A |
||
Power factor |
> 0.99 (0.8 leading - 0.8 lagging) |
|||||
THDi |
< 3% |
|||||
Input AC (Grid side) |
||||||
Max. input current |
250 A |
|||||
Output AC (Back-up) |
||||||
Rated output power |
75 kW |
80kW |
100kW |
125kW |
||
Max. apparent output power |
1.2 times of rated power, 10 mins; 1.4 times of rated power, 100 s; 1.6 times of rated power, 10 s; 2 times of rated power, 200 ms |
1.2 times of rated power, 100 s 1.4 times of rated power, 10 s 1.6 times of rated power, 200 ms |
||||
Back-up switch time |
< 10 ms |
|||||
Rated output voltage |
3/N/PE, 220 V / 380 V, 230 V / 400 V |
|||||
Rated frequency |
50 Hz / 60 Hz |
|||||
THDv (@linear load) |
<2 % |
|||||
Efficiency |
||||||
Max. efficiency |
97.6% |
|||||
EU efficiency |
97.2% |
|||||
BAT charged / discharged to AC max. efficiency |
97.0% |
|||||
Protection |
||||||
Anti-islanding protection |
Yes |
|||||
Output over current protection |
Yes |
|||||
Short circuit protection |
Yes |
|||||
Integrated DC switch |
Yes |
|||||
DC reverse-polarity protection |
Yes |
|||||
Surge protection |
DC Type II / AC Type II |
|||||
Integrated AFCI 2.0 |
Yes |
Optional |
Optional (Brazil: Yes) |
|||
Protection class / Over voltage category |
|
|||||
|
I / II |
|||||
General Data |
||||||
Max. allowable phase imbalance (grid & back-up) |
100% |
|||||
Max. power per phase (grid & back-up) |
25.00 kW |
26.66 kW |
33.33 kW |
41.66 kW |
||
Dimensions (W × H × D) |
1174 x 814 x 400 mm |
|||||
Weight |
170 kg |
|||||
Topology |
Transformless |
|||||
Operating ambient temperature range |
-25 ~ +60°C |
|||||
Ingress protection |
IP66 |
|||||
Cooling concept |
Intelligent fan-cooling |
|||||
Max. operation altitude |
3000 m |
|||||
Grid connection standard |
G99, VDE-AR-N 4105/VDE V 0124, EN 50549-1&2/EN 50549-10, VDE 0126/UTE C 15/VFR:2019, NTS 631/RD 1699/RD 244/ UNE 206006/UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA,PORTARIA Nº 140, DE 21 DE MARÇO DE 2022; Brazil (75K: ORDINANCE (PORTARIA) NO.140, ORDINANCE NO. 515; 100K/125K: NBR 16149, NBR 16150, IEC 62116) |
|||||
Safety / EMC standard |
IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4, EN 55011 |
|||||
Features |
||||||
PV connection |
MC4 Quick connection plug |
|||||
Battery connection |
Terminal connector |
|||||
AC connection |
Terminal block |
|||||
Display |
7.0" LCD display & Bluetooth + APP |
|||||
Communication |
CAN, RS485-115200, Ethernet, Optional: Wi-Fi, Cellular, LAN |
- single or three-phase:
- three-phase
- Battery Voltage:
- 300 - 950 V
- Frequency:
- 50
- Voltage:
- 380