Solis 16KW Single Phase LV Hybrid Inverter
SolisLog in for pricing
S6-EH1P(12-16)K03-NV-YD-L series energy storage inverter is suitable for large residential PV energy storage system, support up to 40A MPPT current input, suitable for 182mm/210mm solar panels; integrated battery treatment and protection functions, more friendly to batteries. And can support multiple inverters in parallel to form a single-phase or three-phase system, the maximum power of 160kW. also support AC couple to retrofit existing solar system; Maximum 350A charging and discharging current, providing higher energy density. Intelligent and reliable, make it the first choice for large-scale residential PV energy storage system.
Leading Features:
- 10 seconds of 200% overload capability
- Multiple inverters can operate together to form a microgrid
- Generator-compatible to extend backup duration during grid power outage
- Supports dual backup ports for intelligent control of critical and non-critical loads
- Automatic switchover time is <4ms, providing seamless transitions from grid to backup
- Supports a maximum input current of 20A, making it ideal for all high-power PV modules of any brand
- Ensures excellent power supply stability, keeping the load unaffected by a weak grid or generator supply fluctuations
- The battery's DC side can handle a maximum charge/discharge current of up to 290A, allowing it to store more surplus energy generated by PV systems
Datasheet:
S6-EH1P(12-16)K03-NV-YD-L |
|||
Models |
12K |
14K |
16K |
Input DC |
|||
Recommended max. PV array size |
24 kW |
28 kW |
32 kW |
Max. usable PV input power |
19.2 kW |
22.4 kW |
22.4 kW |
Max. input voltage |
550 V |
||
Rated voltage |
380 V |
||
Start-up voltage |
100 V |
||
MPPT voltage range |
80 - 520 V |
||
Max. input current |
40 A / 40 A / 40 A |
||
Max. short circuit current |
50 A / 50 A / 50 A |
||
MPPT number / Max. input strings number |
3/6 |
||
Battery |
|||
Battery type |
Li-ion / Lead-acid |
||
Battery voltage range |
40 - 60 V |
||
Max. charge / discharge current |
250 A |
290 A |
290 A |
Communication |
CAN / RS485 |
||
Output AC (Grid side) |
|||
Rated output power |
12 kW |
14 kW |
16 kW |
Operation phase |
L/N/PE |
||
Rated grid voltage |
220 V / 230 V |
||
Rated grid frequency |
50 Hz / 60 Hz |
||
Rated grid output current |
54.5 A / 52.2 A |
63.6 A / 60.9 A |
72.7 A / 69.6 A |
Power factor |
> 0.99 (0.8 leading - 0.8 lagging) |
||
THDi |
< 3% |
||
Input AC (Grid side) |
|||
Input voltage range |
187 - 253 V |
||
Max. input current |
81.8 A / 78.3 A |
95.5 A / 91.3 A |
109.1 A / 104.3 A |
Frequency range |
45 – 55 Hz / 55 – 65 Hz |
||
Output AC (Back-up) |
|||
Rated output power |
12 kW |
14 kW |
16 kW |
Max. apparent output power |
2 times of rated power, 10s |
||
Back-up switch time |
<4ms |
||
Rated output voltage |
L/N/PE,220V / 230V |
||
Rated frequency |
50 Hz / 60 Hz |
||
Rated output current |
54.5 A / 52.2 A |
63.6 A / 60.9 A |
72.7 A / 69.6 A |
THDv (@linear load) |
<3% |
||
Input Generator |
|||
Max. input power |
12 kW |
14 kW |
16 kW |
Max. input current |
54.5 A / 52.2 A |
63.6 A / 60.9 A |
72.7 A / 69.6 A |
Rated input frequency |
50 Hz / 60 Hz |
||
Efficiency |
|||
Max. efficiency |
97.6% |
||
EU efficiency |
97.2% |
||
BAT charged by PV max. efficiency |
>94.9% |
||
BAT charged / discharged to AC max. efficiency |
>94.33% / 93.51% |
||
Protection |
|||
Surge protection |
Yes |
||
DC reverse-polarity protection |
Yes (PV only) |
||
Ground fault monitoring |
Yes |
||
Integrated AFCI 2.0 |
Optional |
||
Protection class / Over voltage category |
I / II (PV and BAT), III (MAINS and BACKUP and GEN) |
||
General Data |
|||
Dimensions (W × H × D) |
464 × 763 × 282 mm |
||
Weight |
48.5 kg |
||
Topology |
Transformerless |
||
Operating ambient temperature range |
-25 ~ +60°C |
||
Ingress protection |
IP66 |
||
Noise emission (typical) |
< 65 dB(A) |
||
Cooling concept |
Intelligent fan-cooling |
||
Max. operation altitude |
4000 m |
||
Grid connection standard |
NRS 097-2-1, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530 |
||
Safety / EMC standard |
IEC/EN 62109-1/-2, EN 61000-6-2/-3 |
||
Features |
|||
DC connection |
MC4 plug (PV port) / Terminal Block (BAT port) |
||
AC connection |
Terminal Block |
||
Display |
7.0" LCD display & Bluetooth + APP |
||
Communication |
RS485, Optional: Cellular, Wi-Fi, LAN |
- single or three-phase:
- single-phase
- Battery Voltage:
- 48
- Frequency:
- 50
- Voltage:
- 220