HOPEWIND 250KW, Three Phase HV String Inverter
Log in for pricing
We ship Internationally!
Contact us for pricing
Log in for pricing
215-255kW three-phase series string inverter have Maximum 28 strings input, support "Y" type connection in DC side. Maximum string input current 15 A, support bifacial modules access. Supports anti-PID function to improve system efficiency. High-precision intelligent strings monitoring reduces fault location time.
Leading Features:
Technical Specifications:
Solis-(215-255)K-EHV-5G |
|||||
Models |
215K-PLUS |
250K |
250K-PLUS |
255K |
255K-PLUS |
Input DC |
|||||
Max. input voltage |
1500 V |
||||
Rated voltage |
1080 V |
||||
Start-up voltage |
500 V |
||||
MPPT voltage range |
480 - 1500 V |
||||
Max. input current |
9 × 30 A |
14 × 26 A |
12 × 30 A |
14 × 26 A |
12 × 30 A |
Max. short circuit current |
9 × 50 A |
14 × 40 A |
12 × 50 A |
14 × 40 A |
12 × 50 A |
MPPT number / Max. input strings number |
9 / 18 |
14 / 28 |
12 / 24 |
14 / 28 |
12 / 24 |
Output AC |
|||||
Output power |
215 kVA@30°C / 205 kVA@ 40°C / 195 kVA@50°C |
250 kVA@30°C / 235 kVA@40°C / 220 kVA@50°C |
255 kVA@30°C / 235 kVA@40°C / 220 kVA@50°C |
||
Rated grid voltage |
3/PE, 800 V |
||||
Grid voltage range |
640 - 920 V |
||||
Rated grid frequency |
50 Hz / 60 Hz |
||||
Max. output current |
155.2 A |
180.4 A |
184.0 A |
||
Power factor |
> 0.99 (0.8 leading - 0.8 lagging) |
||||
THDi |
< 3% |
||||
Efficiency |
|||||
Max. efficiency |
99.0% |
||||
EU efficiency |
98.8% |
98.7% |
98.8% |
98.7% |
98.8% |
Protection |
|||||
DC reverse-polarity protection |
Yes |
||||
Short circuit protection |
Yes |
||||
Output over current protection |
Yes |
||||
Surge protection |
DC Type II / AC Type II |
||||
Grid monitoring |
Yes |
||||
Anti-islanding protection |
Yes |
||||
Temperature protection |
Yes |
||||
Strings monitoring |
Yes |
||||
I/V Curve scanning |
Yes |
||||
Night time SVG function |
Yes |
||||
Integrated PID recovery |
Yes |
||||
Integrated DC Switch |
Yes |
||||
General Data |
|||||
Dimensions (W × H × D) |
1125 × 770 × 384 mm |
||||
Weight |
109 kg |
113 kg |
|||
Topology |
Transformerless |
||||
Self-consumption (night) |
< 2 W |
||||
Operating ambient temperature range |
-30 ~ +60°C |
||||
Relative humidity |
0 - 100% |
||||
Ingress protection |
IP66 |
||||
Cooling concept |
Intelligent fan-cooling |
||||
Max. operation altitude |
4000 m |
||||
Grid connection standard |
EN50549, G99, AS4777.2, VDE0126, IEC61727, VDE4110, CEA 2019 |
||||
Safety / EMC standard |
IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4 |
||||
Features |
|||||
DC connection |
MC4 connector |
||||
AC connection |
OT terminal (max. 300 mm2) |
||||
Display |
LCD |
||||
Communication |
RS485, Optional: PLC |