Solis 80KW Three Phase String Inverter
SolisContact us for pricing
Log in for pricing
80kW three-phase series string inverter adopt 9 MPPT design to provide a more flexible configuration scheme with a smaller environmental impact rate and higher generation efficiency. Max. 16A per string, 150% DC overloading capacity,remote and local intelligent IV scan function.
Leading Features:
- > 150% DC/AC ratio
- Night SVG function
- IP66
- 9 MPPTs, max. efficiency 98.7%
- DC side supports "Y" connector
- Power line communication (PLC) (optional)
- Remote firmware upgrade with simple operation
- AFCI protection, proactively reduces fire risk
- Intelligent string monitoring, smart I-V curve scan
- Globally recognised branded componentry for longer life
- Built-in PID recovery for better module performance (optional)
- String current up to 16A, perfectly match large current bifacial modules
Datasheet:
S5-GC80K |
|
Input DC |
|
Max. input voltage |
1100 V |
Rated voltage |
600 V |
Start-up voltage |
195 V |
MPPT voltage range |
180 - 1000 V |
Max. input current |
9 × 32 A |
Max. short circuit current |
9 × 40 A |
MPPT number / Max. input strings number |
9 / 18 |
Output AC |
|
Rated output power |
80 kW |
Max. apparent output power |
88 kVA |
Max. output power |
88 kW |
Rated grid voltage |
3/N/PE, 220 V / 380 V, 230 V / 400 V |
Rated grid frequency |
50 Hz / 60 Hz |
Rated grid output current |
121.6 A / 115.5 A |
Max. output current |
133.7 A |
Power factor |
> 0.99 (0.8 leading - 0.8 lagging) |
THDi |
< 3% |
Efficiency |
|
Max. efficiency |
98.7% |
EU efficiency |
98.3% |
Protection |
|
DC reverse-polarity protection |
Yes |
Short circuit protection |
Yes |
Output over current protection |
Yes |
Surge protection |
DC Type II / AC Type II |
Grid monitoring |
Yes |
Anti-islanding protection |
Yes |
Temperature protection |
Yes |
Strings monitoring |
Yes |
I/V Curve scanning |
Yes |
Integrated AFCI 2.0 |
Optional |
Integrated PID recovery |
Optional |
Integrated DC switch |
Yes |
Integrated AC switch |
Optional |
General Data |
|
Dimensions (W × H × D) |
1050 × 567 × 314.5 mm (with AC switch) |
Weight |
85 kg |
Topology |
Transformerless |
Self-consumption (night) |
< 2 W |
Operating ambient temperature range |
-30 ~ +60°C |
Relative humidity |
0 - 100% |
Ingress protection |
IP66 |
Cooling concept |
Intelligent fan-cooling |
Max. operation altitude |
4000 m |
Grid connection standard |
G98 or G99, VDE-AR-N 4105/VDE-AR-N 4110/VDE V 0124, EN 50549-1, VDE 0126/UTE C 15/VFR:2019, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530 |
Safety / EMC standard |
IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4 |
Features |
|
DC connection |
MC4 connector |
AC connection |
OT terminal (max. 185 mm2) |
Display |
LCD |
Communication |
RS485, Optional: Wi-Fi, GPRS, PLC |