WECO 16K0 HV 192-273kWh Modular Battery System
WECOContact us for pricing
Log in for pricing
INDUSTRIAL ENERGY STORAGE
Features:
• Scalability - Designed for scalability, allowing seamless expansion to meet growing energy demands by adding multiple units in parallel or stacked configurations. (Allows continuous expansion)
• Integrated WiFi & Bluetooth - Enables effortless wireless communication and remote monitoring, enhancing convenience and flexibility in operation. (RS485, CAN, RS232, (with External Device)
• IP30 - Protected against larger solid objects, It is suitable for dry, indoor environments where exposure to liquids is not a concern.
• Guarantee - Comes with a full 10-year guarantee, ensuring long-lasting performance and reliability for ultimate peace of mind.
Specifications
BATTERY SYSTEM
CABINET / RACK CAPACITY |
MODULES IN SERIES |
MIN. VOLTAGE |
MAX. VOLTAGE |
A-KOOL |
RACK |
192.8 kWh |
12 |
576 VDC |
681,6 VDC |
✓ |
✓ |
208.9 kWh |
13 |
624 VDC |
738,4 VDC |
✓ |
✓ |
225.0 kWh |
14 |
672 VDC |
795,2 VDC |
✓ |
✓ |
241.1 kWh |
15 |
720 VDC |
852 VDC |
✓ |
✓ |
257.1 kWh |
16 |
768 VDC |
908,8 VDC |
X |
✓ |
273.2 kWh |
17 |
816 VDC |
965,6 VDC |
X |
✓ |
BATTERY MODULE
Battery |
Battery System Maximum Capacity |
16.08 kWh |
Battery System Capacity |
16.0 kWh |
|
Single Module Nominal Voltage |
51.2 Vdc |
|
Depth of Discharge |
Up to 98% |
|
Modules Expandability |
Max. 17 per cluster – Up to 8 clusters with HV-HUB |
|
Ingress Protection |
IP30 (or WeCo Cabinet A-Kool) |
|
SYSTEM |
Cluster Net Capacity (min. / max.) |
80,4 kWh / 273,3 kWh |
Module Voltage Range |
46.5 ~ 56,8 Vdc |
|
Cell Capacity |
314 Ah |
|
COMMUNICATION |
Communication Interface |
RS485, CAN, RS232, Wi-Fi & Bluetooth (with External Device) |
BASIC PARAMETERS |
Dimensions (W x D x H) |
482 × 910 × 230 mm |
Weight |
109 kg |
|
Max. Charge / Discharge Current Peak |
Up to 1C max. |
|
Standard Charge / Discharge Current |
0.5C |
|
BMS Working Temperature |
-20 ~ +60 °C |
|
BMS Charge/Discharge Temperature |
-5 ~ +55 °C / -20 °C +55 °C |
|
Recommended Operative Temperature |
+10 °C +35°C |
|
Humidity |
5 % ~ 95 % RH |
|
Altitude |
< 3000 m |
|
Expected Cycle Life @ STC |
> 8000 (25 °C 80% DoD) |
|
Standards |
CB / IEC62368-1 / IEC62619 / CE / UN38.3 |
|
Features |
HV BOX must be used in the system, Three Protection Levels, Real-Time Balancing, Adaptive Charge/ Discharge CAN Logic, 3-Steps Adaptive Charging Logic |
HV BOX
HV BOX |
System Maximum Voltage |
1000 Vdc |
Operative Voltage |
250 ~ 1000 Vdc |
|
Standard Current |
175A |
|
Max. Current |
350A |
|
Min. / Max. Battery Modules Connectable |
Min. 5 ~ Max. 17 |
|
Ingress Protection |
IP30 (WeCo Cabinet Application Only) |
|
SYSTEM |
Start Up Voltage |
250Vdc |
Control Type |
EMS + cascade BMS |
|
Protections |
Main Contactor / Manual Breaker / Fuse |
|
COMMUNICATION |
Communication Interface |
RS485, CAN, RS232, Wi-Fi & Bluetooth |
BASIC PARAMETERS |
Dimensions (W x D x H) |
482 × 910 × 230 mm |
Weight |
24 kg |
|
Pre-charge Circuit |
Yes - Programmable |
|
AUX / IN |
DI/DO programmable + HV Combiner |
|
BMS Working Temperature |
-20 ~ +60 °C |
|
BMS Charge/Discharge Temperature |
-5 ~ +55 °C / -20 °C +55 °C |
|
Recommended Operative Temperature |
+10 °C +35°C |
|
Humidity |
5 % ~ 95 % RH |
|
Altitude |
< 3000 m |
|
Standards |
CB / IEC62368-1 / LVD / CE / IEC 61400 /RoHS |
|
Features |
HV BOX must be used in the system, |
- Voltage:
- 192-273
- Warranty:
- 10