Solis 125KW Three Phase String Inverter (10 MPPT)

Solis
SKU:
S5-GC-125-HV
Availability:
4-6 weeks

Contact us for pricing

Log in for pricing

Weight:
91.00 KGS
Width:
106.50 (cm)
Height:
56.70 (cm)
Depth:
34.45 (cm)
Current Stock:

Download Datasheet

DOWNLOAD DATASHEET

Solis 125KWthreephase10MPPTs,withDCswitch

Features:

Efficient
     - 10 MPPTs, max. efficiency 99.0%
     - > 150% DC/AC ratio
     - High power tracking density 100MPPT/MW
     - String current up to 16A, perfectly match large current bifacial modules
Safe
     - AFCI protection, proactively reduces fire risk
     - Built-in PID recovery for better module performance (optional)
     - Overvoltage load reduction and leakage current suppression technology, low failure rate
     - Globally recognised branded componentry for longer life
Smart
     - Night SVG function
     - Intelligent string monitoring, smart I-V curve scan
     - Remote firmware upgrade with simple operation
Economic
     - Power line communication (PLC) (optional)
     - DC side supports "Y" connector

Datasheet:

Models

100K

110K

125K-HV

Input DC

Max. input voltage

1100 V

Rated voltage

600 V

720 V

Start-up voltage

195 V

MPPT voltage range

180-1000 V

Max. input current

10*32 A

Max. short circuit current

10*40 A

MPPT number/Max. input strings number

10/20

Output AC

Rated output power

100 kW

110 kW

125 kW

Max. apparent output power

110 kVA

121 kVA

137.5 kVA

Max. output power

110 kW

121 kW

137.5 kW

Rated grid voltage

3/N/PE, 220 V / 380 V, 230 V / 400 V

3/PE, 480 V

Rated grid frequency

50 Hz / 60 Hz

Rated grid output current

152.0 A / 144.3 A 

167.1 A / 158.8 A

150.4 A

Max. output current

167.1 A

183.8 A

165.4 A

Power factor

>0.99 (0.8 leading - 0.8 lagging)

THDi

<3%

Efficiency

 

Max. efficiency

98.7%

99.0%

EU efficiency

98.3%

98.6%

Protection

 

 

DC reverse-polarity protection

Yes

Short circuit protection

Yes

Output over current protection

Yes

Surge protection

DC Type II / AC Type II (AC Type I optional)

Grid monitoring

Yes

Anti-islanding protection

Yes

Temperature protection

Yes

Strings monitoring

Yes

I/V Curve scanning

Yes

Integrated PID recovery

Optional

Integrated AFCI (DC arc-fault circuit protection)

Yes (1)

Integrated DC switch

Yes

Integrated AC switch

Optional

General Data

Dimensions (W*H*D)

1065*567*344.5 mm

Weight

91 kg

Topology

Transformerless

Self-consumption (night)

<2 W

Operating ambient temperature range

-30 ~ +60°C

Relative humidity

0-100%

Ingress protection

IP66

Cooling concept

Intelligent redundant fan-cooling

Max. operation altitude

4000 m

Grid connection standard

VDE-AR-N 4105, VDE V 0124, VDE V 0126-1-1, UTE C15-712-1, NRS 097-1-2, G98, G99, EN 50549-1/-2, RD 1699, TOR, UNE 206006, UNE 206007-1, CEI 0-21, IEC61727, DEWA

Safety/EMC standard

IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4

Features

 

 

 

DC connection

MC4 connector

AC connection

OT terminal (max. 185 mm²)

Display

LCD

Communication

RS485, Optional: Wi-Fi, GPRS, PLC

 

5 Years
single or three-phase:
three-phase
Frequency:
50
Voltage:
480