Solis 50KW Three Phase String Inverter
SolisLog in for pricing
Solis 50KWthreephase5MPPT,withDCswith
Features:
• Efficient
- Max. efficiency 98.8%
- String current up to 16A
- 5/6 MPPT design, supports multiple orientation system design
- Night time PID recovery function, increases overall system yield (optional)
• Smart
- Night SVG function
- Supports export power control
- Intelligent string monitoring, smart I-V curve scan
- Scan to register on SolisCloud, supports remote upgrade and control
• Safe
- IP66, C5 Anti-Corrosion LevelAFCI protection, proactively reduces fire risk
- Globally recognised branded componentry for longer life
- Intelligent redundant fan-cooling
- AFCI protection, proactively reduces fire risk
• Economic
- Supports GPRS/WiFi communication with less wiring and reduced installation costs
- DC side supports "Y" connector
- Supports aluminium wire access to reduce cost
- 10/12 string inputs allow for 150%+ DC oversizing
Datasheet:
Models |
50K |
60K |
60K-HV |
70K-HV |
Input DC
Max. input voltage |
1100 V |
||
Rated voltage |
600 V |
720 V |
|
Start-up voltage |
195 V |
||
MPPT voltage range |
180-1000 V |
||
Max. input current |
5*32 A |
6*32 A |
|
Max. short circuit current |
5*40 A |
6*40 A |
|
MPPT number/Max. input strings number |
5/10 |
6/12 |
Output AC
Rated output power |
50 kW |
60 kW |
60 kW |
70 kW |
Max. apparent output power |
55 kVA |
60 kVa |
60 kVa |
70 kVa |
Max. output power |
55 kW |
66 kW |
66 kW |
77 kW |
Rated grid voltage |
3/N/PE, 220 V / 380 V, 230 V / 400 V |
3/PE, 480 V |
||
Rated grid frequency |
50 Hz / 60 Hz |
|||
Rated grid output current |
76.0 A / 72.2 A |
91.2 A / 86.6 A |
72.2 A |
84.2 A |
Max. output current |
83.6 A |
100.3 A |
79.4 A |
92.6 A |
Power factor |
>0.99 (0.8 leading - 0.8 lagging) |
|||
THDi |
<3% |
Efficiency
Max. efficiency |
98.7% |
|
EU efficiency |
98.3% |
98.4% |
Protection
DC reverse-polarity protection |
Yes |
Short circuit protection |
Yes |
Output over current protection |
Yes |
Surge protection |
DC Type II / AC Type II |
Grid monitoring |
Yes |
Anti-islanding protection |
Yes |
Temperature protection |
Yes |
Strings monitoring |
Yes |
I/V Curve scanning |
Yes |
Integrated AFCI (DC arc-fault circuit protection) |
Yes (1) |
Integrated PID recovery |
Optional (2) |
Integrated DC switch |
Optional |
General Data
Dimensions (W*H*D) |
691*578*338 mm |
|||
Weight |
54.5 kg |
|||
Topology |
Transformerless | |||
Self-consumption (night) |
<1 W |
|||
Operating ambient temperature range |
-25 ~ +60°C |
|||
Relative humidity |
0-100% |
|||
Ingress protection |
IP66 |
|||
Cooling concept |
Intelligent redundant fan-cooling |
|||
Max. operation altitude |
4000 m |
|||
Grid connection standard |
G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 / UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, EIFS 2018.2, IEC 62116, IEC 61727, IEC60068, IEC 61683, EN 50530 |
|||
Safety/EMC standard |
IEC 62109-1/-2, IEC62116 & IEC 61000-6-1/-2/-3/-4 |
|||
Features |
|
|
|
|
DC connection |
MC4 connector |
|||
AC connection |
OT terminal (max. 70 mm²) |
|||
Display |
LCD, Capacitive touch buttons |
|||
Communication |
RS485, USB, Optional: Wi-Fi, GPRS |
- single or three-phase:
- three-phase
- Frequency:
- 50
- Voltage:
- 380