Solis 50KW Three Phase String Inverter

Solis
SKU:
S5-GC50K
Availability:
In Stock

Log in for pricing

Weight:
62.20 KGS
Width:
76.00 (cm)
Height:
87.00 (cm)
Depth:
58.40 (cm)
Current Stock:

Download Datasheet

DOWNLOAD DATASHEET

Solis 50KWthreephase5MPPT,withDCswith

Features:

Efficient
     - Max. efficiency 98.8%
     - String current up to 16A
     - 5/6 MPPT design, supports multiple orientation system design
     - Night time PID recovery function, increases overall system yield (optional)
Smart
     - Night SVG function
     - Supports export power control
     - Intelligent string monitoring, smart I-V curve scan
     - Scan to register on SolisCloud, supports remote upgrade and control
Safe
     - IP66, C5 Anti-Corrosion LevelAFCI protection, proactively reduces fire risk
     - Globally recognised branded componentry for longer life
     - Intelligent redundant fan-cooling
     - AFCI protection, proactively reduces fire risk
Economic
     - Supports GPRS/WiFi communication with less wiring and reduced installation costs
     - DC side supports "Y" connector
     - Supports aluminium wire access to reduce cost
     - 10/12 string inputs allow for 150%+ DC oversizing

Datasheet:       

Models

50K

60K

60K-HV

70K-HV

Input DC

Max. input voltage

1100 V

Rated voltage

600 V

720 V

Start-up voltage

195 V

MPPT voltage range

180-1000 V

Max. input current

5*32 A

6*32 A

Max. short circuit current

5*40 A

6*40 A

MPPT number/Max. input strings number

5/10

6/12

Output AC

Rated output power

50 kW

60 kW

60 kW

70 kW

Max. apparent output power

55 kVA

60 kVa

60 kVa

70 kVa

Max. output power

55 kW

66 kW

66 kW

77 kW

Rated grid voltage

3/N/PE, 220 V / 380 V, 230 V / 400 V

3/PE, 480 V

Rated grid frequency

50 Hz / 60 Hz

Rated grid output current

76.0 A / 72.2 A

91.2 A / 86.6 A

72.2 A

84.2 A

Max. output current

83.6 A

100.3 A

79.4 A

92.6 A

Power factor

>0.99 (0.8 leading - 0.8 lagging)

THDi

<3%

Efficiency

Max. efficiency

98.7%

EU efficiency

98.3%   

98.4%

Protection

DC reverse-polarity protection

Yes

Short circuit protection

Yes

Output over current protection

Yes

Surge protection

DC Type II / AC Type II

Grid monitoring

Yes

Anti-islanding protection

Yes

Temperature protection

Yes

Strings monitoring

Yes

I/V Curve scanning

Yes

Integrated AFCI (DC arc-fault circuit protection)

Yes (1)

Integrated PID recovery

Optional (2)

Integrated DC switch

Optional

General Data

Dimensions (W*H*D)

691*578*338 mm

Weight

54.5 kg

Topology

Transformerless

Self-consumption (night)

<1 W

Operating ambient temperature range

-25 ~ +60°C

Relative humidity

0-100%

Ingress protection

IP66

Cooling concept

Intelligent redundant fan-cooling

Max. operation altitude

4000 m

Grid connection standard

G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 /

UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, EIFS 2018.2, IEC 62116, IEC 61727, IEC60068, IEC 61683, EN 50530

Safety/EMC standard

IEC 62109-1/-2, IEC62116 & IEC 61000-6-1/-2/-3/-4

Features

 

 

 

 

DC connection

MC4 connector

AC connection

OT terminal (max. 70 mm²)

Display

LCD, Capacitive touch buttons

Communication

RS485, USB, Optional: Wi-Fi, GPRS

 

 

 

 

 

               

5 Years
single or three-phase:
three-phase
Frequency:
50
Voltage:
380