DEYE 12KW Single Phase Hybrid EU Inverter
DEYELog in for pricing
SUN-12K-SG02LP1-EU-AM3 | Single Phase | Hybrid Inverter
Features :
• Colorful touch LCD, IP65 protection degree
• AC couple to retrofit existing solar system
• Max.16 pcs paralle; for on-grid and off-grid opertion; Support multiple batteries parallel
• Max. charging/discharging current of 250A
• 6 time periods for battery charging /discharghing
• Support storing energy from diesel generator
Technical Specifications:
MODEL |
SUN-10K-SG02LP1-EU-AM3 |
SUN-12K-SG02LP1-EU-AM3 |
Battery Input Data |
||
Battery Type |
Lead-acid or Lithium-Ion |
|
Battery Voltage Range (V) |
40-60 |
|
Max.charging Current (A) |
220 |
250 |
Max.discharging Current (A) |
220 |
250 |
External Temperature Sensor |
Yes |
|
Charging Curve |
3 Stages / Equalization |
|
Charging Strategy for Li-Ion Battery |
Self-adaption to BMS |
|
PV String Input Data |
||
Max. DC Input Power (W) |
13000 |
15600 |
Rated PV Input Voltage (V) |
370 (125-500) |
|
Start-up Voltage (V) |
125 |
|
MPPT Voltage Range (V) |
150-425 |
|
Full Load DC Voltage Range (V) |
200-425 |
|
PV Input Current (A) |
26+26+26 |
|
Max. PV Isc (A) |
44+44+44 |
|
No. of MPP trackers |
3 |
|
No. of string per MPP Tracker |
2+2+2 |
|
AC Output Data |
||
Rated AC Output Active Power (W) |
10000 |
12000 |
Max AC Output Active Power (W) |
11000 |
13200 |
AC Output Rated Current (A) |
45.5/43.5 |
54.6/52.2 |
Max AC Output Current (A) |
50/47.9 |
60/57.4 |
Max. Continuous AC Passthrough (A) |
70 |
|
Peak Power (off grid) |
2 time of rated power, 10S |
|
Power Factor Adjustment Range |
0.8 leading to 0.8 lagging |
|
Power Factor |
1 |
|
Output Frequency and Voltage |
50/60Hz; L/N/PE 220/230Vac |
|
Grid Type |
Split Phase ; 2/3 phase ; Single Phase |
|
Total Harmonic Distortion (THD) |
<3% (of nominal power) |
|
DC Current Injection |
<0.5% In |
|
Efficiency |
||
Max. Efficiency |
97.60% |
|
Euro Efficiency |
97.00% |
|
MPPT Efficiency |
99.90% |
|
Protection |
||
Integrated |
Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protectiob, Output Shorted Protection, Surge Protection |
|
Over Voltage Category |
DC Type II / AC Type III |
|
General Data |
||
Operating Temperature Range (℃) |
-40-60 ℃, >45 ℃ Derating |
|
Cooling |
Smart Cooling |
|
Noise (dB) |
<30dB |
|
Communication with BMS |
RS485;CAN |
|
Weight (KG) |
32 |
|
Cabinet Size (WxHxD mm) |
420x670x233 (excluding connectors and brackets |
|
Protection Degree |
IP65 |
|
Installation Style |
Wall-mounted |
|
Warranty |
5 years (10 years optional) |
- single or three-phase:
- single-phase
- Frequency:
- 50
- Voltage:
- 220
- Battery Voltage:
- 48