Solis 125KW Three Phase String Inverter
SolisLog in for pricing
Solis S6-GC(100-125)K three-phase series inverter is a new S6 models, designed for C&I and utility PV projects. it input current up to 21A, can perfectly match a variety of high-power PV panels, the maximum support 150%DC/AC ratio, while supporting PLC communication, AC and DC cable design optimization, intelligent I-V curve scanning and remote O&M functions, can effectively reduce system costs and simplify O&M, improve system efficiency, very suitable for cost reduction and efficiency of PV plant projects. moreover, the product has IP66 protection grade, and the inverter can easily cope with complex and harsh natural environments.
Leading Features:
- IP66
- >150% DC/AC ratio
- Supports export power control
- 10 MPPTs, max. efficiency 98.7%
- DC side supports "Y" connector
- AFCI protection, proactively reduces fire risk
- Power line communication (PLC) (optional)
- Intelligent string monitoring, smart I-V curve scan
- Remote firmware upgrade with simple operation
- Globally recognised branded componentry for longer life
- String current up to 21A, perfectly match large current bifacial modules
- Night time PID recovery function, increases overall system yield (optional)
Datasheet:
S6-GC(100-125)K |
|||
Models |
100K |
110K |
125K |
Input DC |
|||
Max. input voltage |
1100 V |
||
Rated voltage |
600 V |
||
Start-up voltage |
180 V |
||
MPPT voltage range |
160 - 1000 V |
||
Max. input current |
5 × (42 A / 36 A) |
||
Max. short circuit current |
10 × 50 A |
||
MPPT number / Max. input strings number |
10/20 |
||
Output AC |
|||
Rated output power |
100 kW |
110 kW |
125 kW |
Max. apparent output power |
110 kVA |
121 kVA |
125 kVA |
Max. output power |
110 kW |
121 kW |
125 kW |
Rated grid voltage |
3/N/PE, 220 V / 380 V, 230 V / 400 V |
||
Rated grid frequency |
50 Hz |
||
Rated grid output current |
152.0 A / 144.3 A |
167.1 A / 158.8 A |
189.9 A / 180.4 A |
Max. output current |
167.1 A |
183.8 A |
189.9 A |
Power factor |
> 0.99 (0.8 leading - 0.8 lagging) |
||
THDi |
< 3% |
||
Efficiency |
|||
Max. efficiency |
98.7% |
||
EU efficiency |
98.3% |
||
Protection |
|||
DC reverse-polarity protection |
Yes |
||
Short circuit protection |
Yes |
||
Output over current protection |
Yes |
||
Surge protection |
DC Type II / AC Type II |
||
Grid monitoring |
Yes |
||
Anti-islanding protection |
Yes |
||
Temperature protection |
Yes |
||
Strings monitoring |
Yes |
||
I/V Curve scanning |
Yes |
||
Integrated AFCI 2.0 |
Optional |
||
Integrated PID recovery |
Optional |
||
Integrated DC switch |
Yes |
||
Integrated AC switch |
Optional |
||
General Data |
|||
Dimensions (W × H × D) |
1014 × 567 × 345 mm |
||
Weight |
96 kg |
||
Topology |
Transformerless |
||
Self-consumption (night) |
< 2 W |
||
Operating ambient temperature range |
-30 ~ +60°C |
||
Relative humidity |
0 - 100% |
||
Ingress protection |
IP66 |
||
Cooling concept |
Intelligent fan-cooling |
||
Max. operation altitude |
4000 m |
||
Grid connection standard |
G99, IEC61727, EN50549-1/2, VDE4110 |
||
Safety / EMC standard |
IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4 |
||
Features |
|||
DC connection |
MC4 connector |
||
AC connection |
OT terminal (max. 240 mm2) |
||
Display |
LCD |
||
Communication |
RS485, Optional: Wi-Fi, GPRS, PLC |