3.6KW, 220V Single Phase String Inverter, ALL STRING INVERTER AND HYBRID INVERTER ARE INCLUDED WIFI PLUG

Features:

  • 2 MPP tracker, Max. efficiency up to 97.5%
  • Zero export application, VSG application
  • String intelligent monitoring (optional)
  • Wide output voltage range

Datasheet:

Model

SUN-3.6K-G04

SUN-4K-G04

SUN-4.6K-G04

SUN-5K-G04

SUN-6K-G04

Input Side

Max. DC Input Power(kW)

4.7

5.2

5.98

6.5

7.8

Max. DC Input Voltage (V)

550

Start-up DC Input Voltage(V)

80

MPPT Operating Range(V)

70-550

Max. DC Input Current(A)

13+13

Max. Short Circuit Current (A)

19.5+19.5

Number of MPPT/Strings per MPPT

2/1

Output Side

Rated Output Power(kW)

3.6

4

4.6

5

6

Max. Active Power(kW)

3.96

4.4

5.06

5.5

6.6

Rated AC Grid Voltage(V)

L/N/PE 220 / 230 (optional)

AC Grid Voltage Range(V)

180Vac~300Vac(this may vary with grid standards)

Rated Grid Frequency(Hz)

50 / 60 (Optional)

Operating Phase

Single phase

Rated AC Grid Output Current(A)

16.4/15.7

18.2/17.4

20.9/20

22.7/21.7

27.3/26.1

Max. AC Output Current(A)

18/17.2

20/19.1

23/22

25/23.9

30/28.7

Output Power Factor

0.8 leading to 0.8 lagging

Grid Current THD

<3%

DC Injection Current(mA)

<0.5%

Grid Frequency Range

47~52 or 57~62 (Optional)

Efficiency

Max.Efficiency

97.3%

97.5%

97.5%

97.5%

97.5%

Euro Efficiency

97.1%

97.3%

97.3%

97.3%

97.3%

MPPT Efficiency

>99%

Protection

DC Reverse-Polarity Protection

Yes

AC Short Circuit Protection

Yes

AC Output Overcurrent Protection

Yes

Output Overvoltage Protection

Yes

Insulation Resistance Protection

Yes

Ground Fault Monitoring

Yes

Abti-islanding Protection

Yes

Temperature Protection

Yes

Integrated DC Switch

Yes

Remote software upload

Yes

Remote change of operating parameters

Yes

Surge protection

DC Type II / AC Type II

General Data

Size(mm)

330W×323H×190D

Weight(kg)

7.5

Topology

Transformerless

Internal Consumption

<1W(Night)

Running Temperature

-25~65℃,>45℃ derating

Ingress Protection

IP65

Noise Emission(Typical)

<35 dB

Cooling Concept

Natural cooling

Max. Operating Altitude Without Derating

2000m

Designed Lifetime

5years

Grid Connection Standard

VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1, G98, G99, C10-11, UNE217002, NBR16149/NBR16150

Operating Surroundings Humidity

0-100%

Safety EMC/Standard

   IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Features

DC Connection

MC-4 mateable

AC Connection

IP65 rated plug

Display

LCD 1602

Interface

RS485/RS232/Wifi/LAN

5 Years + 2 years Nastech exclusive = 7 Years
single or three-phase:
single-phase
Frequency:
50
Voltage:
220