LUXPOWER 12KW Single Phase Hybrid Inverter
LuxPowerLog in for pricing
LuxPower Hybrid Inverter LXP-LB-EU 12K
Features:
- Max 250A charge/discharge current with 48v battery
- Paralleling up to 6 units
- AC-coupling function
- Smart load control
- Separate generator interface available
- 12kW UPS output single phase
- 3 MPPT inputs, maximum up to 18 kW
- Integrated UPS module, on/off grid seamless
- LCD color touch screen
Datasheet:
INPUT (PV DC) |
LXP-LB-EU 12K |
Max. PV array power(W) | 18000W |
Rated PV input voltage(V) |
360 |
Number of independent MPPT inputs |
3 |
PV input voltage range(V) | 100 600 |
MPPT voltage range(V) | 120 480 |
Start-up voltage(V) |
140 |
Max. PV input current per MPPT(A) |
25/15/15 |
Max. PV short-circuit current input per MPPT(A) |
31/19/19 |
Battery |
|
Compatible Battery Type |
Lithium-ion / Lead-Acid |
Rated battery voltage(Lithium-ion/Lead-Acid)(V) |
48 |
Battery voltage range(V) |
40 60 |
Max. charging/discharging current(V) |
250 |
Max. charging power(W) |
12000 |
Force wake up battery from PV function(Y/N) | Y |
Grid |
|
Rated AC voltage(V) |
230 |
Rated AC frequency(Hz) |
50 |
Rated AC output current(A) |
50 |
Rated AC output power(W) |
11500 |
Max. AC intput current(A) |
100 |
Max. AC intput power(W) |
23000 |
PF |
0.99 |
THDI |
<3% |
Rated AC current of BYPASS relays(A) |
200 |
UPS |
|
Rated output power(W) |
11500 |
Rated output voltage(V) |
230 |
Rated output current(A) |
50 |
Rated output frequency(Hz) |
50 / 60 |
Surge power, duration | 2Pn, 0.5s |
Switching time | 20ms |
Wave form | Sine Wave |
THDV | 3% |
Efficiency |
|
Max. MPPT efficiency | 99.0% |
Max.Efficiency | 99.0% |
EU Efficiency | 97.5% |
Max. Charging Efficiency | 96.0% |
Max. Discharging Efficiency | 94.0% |
Protection |
|
PV reverse polarity protection |
YES |
Over current/voltage protection |
YES |
Anti-islanding protection |
YES |
AC Short-circuit current protection |
YES |
Leakage current protection |
YES |
Ground fault monitoring |
YES |
Grid monitoring | YES |
DC Switch |
YES |
AC/DC Surge protection Type III |
YES |
General |
|
Dimensions (W/H/D) |
490*670*265mm/19.3*26.3*10.4inch |
Weight | 50kg/110.2lbs |
Ingress protection rating | IP65 |
Relative humidity | 0 100% |
Operating environment temperature range | -25 60°C |
Storage temperature range | -25 60°C |
Display & Communication interface | Touch color screen, RS485/Wi-Fi/CAN |
Warranty | 5 years |
Cooling Method | FAN |
Topology | Transformer-less |
Altitude | <2000m |
Noise emission(typical) | <50dB |
Standard & Certification |
|
EU Version NRS 097 |
- single or three-phase:
- single-phase
- Frequency:
- 50
- Voltage:
- 220
- Battery Voltage:
- 48