WECO 115kWh A-KooL 1C Energy Storage System
WECOContact us for pricing
Log in for pricing
Model Name |
A-Kool-115 |
|
Battery |
Battery Type |
7K6 Lithium Iron Phosphate |
Cell Specifications |
3.2 V, 150 Ah |
|
Pack Construction |
16S |
|
Battery Capacity |
7.68 kWh |
|
Max DoD |
90% |
|
System |
Rated Capacity |
115 kWh |
Cabinet Max Slots (Standard) |
15+1 HVBOX |
|
Rated Voltage |
768 VDC |
|
Voltage Range |
680 ~ 864 Vdc | |
Peak Current |
1C (150A) |
|
Recommended Discharge/Charge Current (Peak) |
0.5C (75 A) |
|
System Short Circuit Current |
7000 A |
|
Battery Short Circuit System |
6800 A |
|
HV Box Fuses Protection |
1000V-200A on both poles |
|
HV Box Manual Breaker Rating |
1500 V – 200 A Type C Automatic Thermal Protection |
|
HV Box BMS-controlled Contractor Current Rating |
350 A On Both Poles |
|
Cabinet Max Elevation |
3000m |
|
Cycles |
Number of Cycles @0.5C |
≥ 7000 (0.5C,90%DOD,70%SOH) |
|
Number Of Cycles 1C |
≥4700 (1C,90%DOD, 70%SOH) |
Communication |
Battery to Inverter Communication |
CAN |
AUX Data Communications – MODBUS |
RS485 |
|
APP Connectivity |
WeCo NooR App |
|
Cloud Platform |
LAN+4G |
|
BMS Protections |
SOC Alerts |
Built-in |
Cell Over- and Under-Voltage Protection |
Built-in |
|
Overload Protection |
Built-in |
|
High Temperature Alarm |
Built-in |
|
Passive Protections |
External Stop Button (Contractor Disconnection Impulse) |
Built-in |
Smoke Alarm |
Built-in |
|
Top Windows Pressure Release |
Built-in |
|
Fire Detection Sensor |
Built-in |
|
Fire Fighting System/Gas Suppression Aerosol |
Built-in |
|
DC Protection |
Built-in |
|
Storage Requirements |
Storage Max Humidity |
RH ≤ 95% (No condensation) |
Storage Temperature |
Less than 3 months: 0 ~ 45 °C (SOC: 20% ~ 50%) |
|
Shelf Life Without Inspections |
> 3 months: 15 ~ 35 °C (SOC: 20% ~ 50%) |
|
Storage Elevation |
≤3000m |
|
Dimensions (W*D*H) |
1140x1190x2300mm |
|
Basic Parameters |
Weight |
1650kg |
Cabinet Design Working Temperature Range |
-20 °C +45 °C (Derating due to Defrost Cycles to be considered) |
|
Recommended Temperature Range |
-10 °C +45 °C |
|
Defrost Coil Resistor For Extreme Low Temperature |
220V AC Heating Resistor For Defrosting Function (Optional) |
|
IP Rating |
IP55 |
|
Cooling Method |
Heat Pump & Air Conditioning |
|
A/C Stand By Consumption (Inactive Compressor Status Via EMS) |
50W | |
A/C Max. Cooling Power |
1200 W |
|
A/C Max. Heating Power |
2500 W | |
A/C Consumption With Compressor OFF And Fan Running For Air Circulation Only |
250 W |
|
HV BOX Self Consumption |
15 W |
|
HV BOX Consumption With All Fan Running Full Speed |
75 W |
|
Energy Saving Programming Mode |
Scheduling via EMS for Full Energy Saving |
|
Coating |
Standard Outdoor Painting |
|
Shipping Method |
Batteries to be installed on site |
- Ampere-hour:
- 150
- Warranty:
- 10